Biotage V-10 Touch Evaporator
The Biotage® V-10 Touch Evaporation System is an innovative, fully automated solution designed to streamline sample drying and solvent removal in organic synthesis, peptide synthesis, and purification workflows. Specifically built to handle high boiling point solvents such as DMF and NMP, as well as HPLC fractions, the V-10 Touch enables chemists to bypass traditional, labor-intensive liquid-liquid extraction methods—saving time, reducing manual handling, and improving reproducibility. The V-10 Touch simplifies complex evaporation processes like dry-down onto silica for easier dry load preparation prior to purification. With walk-up, walk-away capability and consistent performance, the system enhances efficiency in peptide cleavage cocktail removal and accelerates compound isolation, delivering high-value products faster with fewer steps.
- Handles High-Boiling Point Solvents — Easily evaporates NMP, DMF, and other challenging solvents.
- Dries HPLC Fractions & Organic Samples — Supports both aqueous and organic solvents with fast evaporation times.
- Dry-down onto Silica Capability — Simplifies dry load prep for downstream purification.
- Reduces Manual Handling — Minimizes sample transfer and vial reformatting for safer, faster workflows.Automated Walk-away Operation — Consistent, reproducible evaporation performance for busy labs.
- Enhances Synthetic Flexibility — Allows wider solvent choice for organic and peptide synthesis.
- Accelerates Peptide Isolation — Enables faster removal of cleavage cocktails and purification steps.
- Minimizes Work-up Steps — Cuts down the number of extraction and transfer operations needed in synthetic workflows.
- Organic Compound Synthesis
- Peptide Synthesis & Purification
- HPLC Fraction Evaporation
- Solvent Removal in Chemical Reactions
- Dry Load Preparation for Flash Purification
- Pharmaceutical & Biotech R&D
| Specification | Details |
|---|---|
| Solvent compatibility | Boiling points from 30–160 °C (up to 205 °C with an external vacuum pump). Not suitable for solutions containing HCl at any concentration. |
| Heating | 20 °C – 70 °C |
| Rotational speed | 3000 – 8000 rpm |
| Max power consumed | 2100 VA |
| Condenser | Refrigerated condenser, -25 °C. Automated and manual draining, manual defrost. |
| Exhaust | Double trapping |
| Weight | 50 kg (110 lbs.) |
| Vial size | 30 mL scintillation vial, 20 mL scintillation vial, 16 mL vial, 8 mL vial, 4 mL (3 variants) |
| Electrical supply | 220–240 V~, 50/60 Hz, 10 A |
| Vacuum | Pressure control method: variable speed and level. Internal vacuum pump: 5 mbar. Optional external vacuum pump connection via KF-16 flange. |
| Dimensions | Footprint (W × D): 400 × 480 mm (15.7” × 18.9”); Height: 530 mm (20.9”) |