High Concentration Condensation Particle Counter 3752

The High Concentration Condensation Particle Counter (CPC) Model 3752 is engineered for precise measurement of extremely high particle concentrations. With a single particle counting mode up to 100,000 particles/cm³ and extended photometric mode up to 10,000,000 particles/cm³, this CPC is ideal for advanced aerosol science, filter testing, and combustion research. Backed by 40+ years of TSI expertise, the 4th generation CPC 3752 combines superior sensitivity, high-speed data acquisition, and intuitive touch-screen control for unmatched performance in real-time nanoparticle monitoring.

Contact Us for a Quote
Features
  • Counts up to 100,000 particles/cm³ in single-particle mode
  • Photometric detection for concentrations up to 10,000,000 particles/cm³
  • Detects particles down to 4 nm (D50)
  • High-speed data acquisition at 50 Hz for fast-changing aerosols
  • Robust internal memory for storing weeks of continuous data
  • Touchscreen interface and improved software for intuitive operation
  • Water-removal system for high-humidity environments
  • Pulse Height Monitoring (PHM) for enhanced diagnostics
  • Fast T10-90 response under 1.5 seconds for rapid particle changes
  • Fully integrated with TSI SMPS™ Series 3938 systems
Applications
  • High-volume filter efficiency testing
  • Combustion and engine emissions studies
  • Basic and advanced aerosol research
  • Atmospheric and climate research
  • Health exposure and air quality studies
  • Nanomaterial generation and safety analysis
  • Filter and media manufacturing
  • Combustion and automotive R&D
Specifications
Parameter Specification
Particle Size Range 4 nm minimum detectable (D50), verified with monodisperse sucrose particles; >3 µm maximum detectable particle size
Particle Concentration Range Up to 100,000 (1×10⁵) particles/cm³ with single particle counting & continuous live-time coincidence correction; extended to 10,000,000 (1×10⁷) particles/cm³ with photometric detection
Particle Concentration Accuracy ±5% at <100,000 particles/cm³ (single-counting); ±20% at <10,000,000 particles/cm³ (photometric)
False Background Counts <0.01 particles/cm³ (12-hour average)
Response Time High flow: <1.5 s (T10–90, T90–10), <3 s (T95) Low flow: <2 s (T10–90, T90–10), <4 s (T95)
Flow System 0.3 ± 0.015 L/min or 1.5 ± 0.05 L/min inlet flow (volumetric); 0.3 ± 0.015 L/min counting flow (volumetric)
Liquid System Butanol (n-Butyl alcohol, not included) as working fluid; internal water removal pump recommended in humid environments
Ambient Operating Conditions Temperature: 10–35 °C (50–95 °F); Humidity: 0–90% RH (non-condensing); Pressure: 75–105 kPa (0.75–1.05 atm)
Electrical 100–240 VAC, 50/60 Hz, 335 W max
Data Storage Internal memory for ~1 year at 50 Hz data rate
Weight ~9.1 kg (20 lbs)
Dimensions (L × W × H) 30.0 × 28.6 × 34.3 cm (11.83 × 11.05 × 13.54 in), excluding fill bottle & bracket